Flow Cytometry Flow Cytometer - Flow Cytometry - Bioway Biological Technology Co.,Ltd
español русский English 中文

Location:Home >
Product Name:Flow Cytometry Flow Cytometer
Details

Flow Cytometry


详情图.jpg

0_2.jpg


Specification of Flow Cytometry

Optical System:

1. Laser configuration: 488nm solid-state laser is used, which can excite at least four fluorescent dyes at the same time, laser power ≥40mW;

Laser source

Fluorescence Channel

Recommended Fluorescent Fuel

488nm

FL1:530/30nm

FITC

FL2:585/40nm

PEPI

FL3:670LP

PE-Cy5.5PC5PC5.5PerCPPerCP-Cy5.5

FL4:785/60nm

PE-Cy7PC7

2. Spatial three-dimensional excitation mode, fixed optical path without adjustment, overall temperature control of the optical system;

3. Linear optical path design, optical filters can be replaced with experimental needs;

4. The instrument is equipped with an avalanche photodiode (APD) to improve photoelectric conversion efficiency;


Analytical Performance:

1. Fluorescence sensitivity: FITC≤200MESF, PE≤100MESF;

2. Fluorescence Linearity:≥0.98;

3. Instrument detection resolution (full peak width CV of forward angle scattered light and fluorescence channel): FSC≤2.0%; FL1(FITC) ≤2.0%; FL2(PE)≤2.0%;

4. Resolution of forward angle scattered light and lateral angle scattered light: able to separate red blood cells and platelets in peripheral blood; able to separate the three groups of white blood cells (lymphocytes, monocytes and granulocytes) in peripheral blood;

5. Detection sensitivity of forward angle scattered light : ≤1.0μm;

6. Test carrying contamination rate ≤0.5%, after each test is completed, the flow chamber sample needle can be automatically cleaned to avoid cross contamination

7. Highest event rate : ≤50000 cells per second;

8. Compatible volume method and microsphere method absolute counting;


Sample Loading System:

1. Use a syringe to load the sample;

 

2. Compatible with a variety of centrifuge tubes and flow cytometry tubes;

3. With four different speed modes for sample loading, different modes can be selected according to actual sample processing requirements;

Sample speed adjustment

High Speed

Medium Speed

Low Speed

Sheath Speed

124uL/min

82uL/min

33uL/min

12mL/min


Software System:

1. Full-matrix fluorescence compensationthe instrument supports online and offline compensation;

2. The single software supports data acquisition and data analysis at the same time and can edit reports on the software, and can directly generate FCS files without special operating software;

3. The operating system supports Microsoft WIN10 system;


Others:

The host can be placed in a single clean bench for test operations


Product Physical Characteristics :

Dimension:250mm*280mm*250mm

Weight10KG

Power Supply AC 100-240V50/60Hz




0.0636s